An analysis of reducing back-flashover faults with surge arresters on 69/138-kV double-circuit transmission lines due to direct lightning strikes on the shield wires

  • WhatsApp
  • Facebook
  • Email
  • LinkedIn
  • Bluesky
CPD This content can contribute towards your Continuing Professional Development (CPD) as part of the IET's CPD Monitoring scheme.
Conference
  • Session
  • Wednesday, 02 April 2014
  • 00:00
  • Duration: 19 mins
  • Publication date: 02 Apr 2014
  • Location: IETTV_Room, IETTV_Venue, Copenhagen, Denmark
  • Part of event DPSP 2014 - 12th IET International Conference on Developments in Power System Protection: Protecting the Green Grid

About the session

Back flashover faults resulting from lightning strokes hitting the shield wire(s) or tower(s) are one of the major causes of power interruptions on the double-circuit 69/138 kV overhead transmission lines in Jamaica. Computational analysis with the aid of Alternative Transient Program-Electromagnetic Transient Program (ATP-EMTP) simulations was performed on a section of the affected lines to identify the main factors causing back flashover faults with an attempt to reduce the effects and to improve both power reliability and financial losses. A model of the selected line section suitable for transient overvoltage studies was developed to investigate fast transient studies of flashover occurrences of the line insulator with respect to lightning amplitudes and wave fronts; as well as the tower footing impulse resistances and the tower surge impedance. The results show that the 69 kV transmission line was more sensitive to flashover faults, which was due mainly to its relatively lower basic lightning impulse insulation level (BIL) of the line insulators, compared to the 138 kV line. However, the results also indicate that the installation of surge arresters on the affected towers significantly reduce the transient overvoltages well below the insulators' withstand voltages and thereby providing effective protection against back flashover faults. The energies absorbed by the surge arresters were also investigated and presented herein.

Channels

Power

Power

Speaker

  • NM

    Newman Malcolm

    University of Bath, Faculty of Engineering & Design

The Institution of Engineering and Technology iet.tv

Address: Futures Place, Kings Way, Stevenage, SG1 2UA

Telephone: +44 (0)33 049 9123

Email:  iet.tv@theiet.org

© 2026 The Institution of Engineering and Technology.

The Institution of Engineering and Technology is registered as a Charity in England & Wales (no 211014) and Scotland (no SC038698). Futures Place, Kings Way, Stevenage, Hertfordshire, SG1 2UA, United Kingdom

  • LinkedIn
  • Instagram
  • YouTube
Privacy statement Cookie Preferences Accessibility About us theiet.org Help

Powered by Cadmore Media

Embed Code

<script type="text/javascript" src="https://play.cadmore.media/js/EMBED.js"></script> <div class="cmpl_iframe_div"> <iframe src="https://play.cadmore.media/Player/f19c7cfc-c4af-4887-87b2-2662e4b00f9c" scrolling="no" allowtransparency="true" allowautoplay="true" frameborder="0" allow="encrypted-media;autoplay;fullscreen" class="cmpl_iframe" allowfullscreen="" style="overflow: hidden;border: 0px; margin: 0px; height: 100%; width:100%;"></iframe> </div>

Are you sure you want to reset your password?

If so, you will be redirected to the Authentication Service

Title

Prompt