Skip to main content
The Institution of Engineering and Technology iet.tv
Site name
  • Videos
  • Channels
  • Events
  • Series

Access and Account

Access your personal account

Log in to see your favourites, lists and progress.

IET Login

Access via institution

Not currently connected to any institutions

Connect via

This video isn’t available to you right now

Login to check your access and watch the full session

Login
  1. Videos
  2. Video

A new inrush detection algorithm for transformer differential protection

  • WhatsApp
  • Facebook
  • Email
  • LinkedIn
  • Bluesky
CPD This content can contribute towards your Continuing Professional Development (CPD) as part of the IET's CPD Monitoring scheme.
Conference
  • Session
  • Wednesday, 02 April 2014
  • 00:2 - 00:2
  • Duration: 19 mins
  • Publication date: 02 Apr 2014
  • Location: IETTV_Room, IETTV_Venue, Copenhagen, Denmark
  • Part of event DPSP 2014 - 12th IET International Conference on Developments in Power System Protection: Protecting the Green Grid

About the session

Some power transformers, especially new designs with the core material improved for lower losses, produce low levels of second harmonic in their inrush magnetizing currents. Transformer differential relays face security problems when the second harmonic falls below the traditional 15 or 20% setting level. This paper derives a new protection method for detecting inrush conditions. The new algorithm is based on dwell-time periods in the inrush current. In each power cycle of a true inrush current, a period occurs where the differential current is both small and flat (dwell time). The new algorithm combines the absolute values of the instantaneous differential current with the absolute values of the differential current derivative to positively confirm both the low level and the flatness of the dwell-time currents. By utilizing the "flatness" feature of the wave shape, the algorithm performs well even under current transformer (CT) saturation. The new algorithm incorporates a separate method to cancel the inrush inhibit signal, allowing very fast operation for internal faults, particularly during inrush conditions. This dedicated element is based on a bidirectional instantaneous overcurrent principle.

Channels

Power

Power

Speaker

  • BK

    Bogdan Kasztenny

    Schweitzer Engineering Laboratories, Inc.

The Institution of Engineering and Technology iet.tv

Address: Futures Place, Kings Way, Stevenage, SG1 2UA

Telephone: +44 (0)33 049 9123

Email:  iet.tv@theiet.org

© 2026 The Institution of Engineering and Technology.

The Institution of Engineering and Technology is registered as a Charity in England & Wales (no 211014) and Scotland (no SC038698). Futures Place, Kings Way, Stevenage, Hertfordshire, SG1 2UA, United Kingdom

  • LinkedIn
  • Instagram
  • YouTube
Privacy statement Cookie Preferences Accessibility About us theiet.org Help

Powered by Cadmore Media

Embed Code

<script type="text/javascript" src="https://play.cadmore.media/js/EMBED.js"></script> <div class="cmpl_iframe_div"> <iframe src="https://play.cadmore.media/Player/5e0416e1-c4e6-410b-a73b-00f541a64030" scrolling="no" allowtransparency="true" allowautoplay="true" frameborder="0" allow="encrypted-media;autoplay;fullscreen" class="cmpl_iframe" allowfullscreen="" style="overflow: hidden;border: 0px; margin: 0px; height: 100%; width:100%;"></iframe> </div>

Are you sure you want to reset your password?

If so, you will be redirected to the Authentication Service

Title

Prompt